菜单

Purifying device of hydrogen-removed oxygen

Share
  • parameter
  • principle
  • Technology
  • To configure
  • Introduce
    • Oxygen concentration of feed:<2%

      Feed pressure:0.3MPa~0.7MPa

      Residue index:

      0xygen content:≤1ppm

      Hydrogen content ≤ 1000 ppm (Exception to hydrogen purification project)

      Dust:≤0.01μm

      Dew point:≤-60℃


      Hydrogen and ordinary nitrogen gas containing oxygen less than 2 % are mixed and flow into the purification device oxygen remover. The small amount of oxygen is completely reacted to generate water with the excess hydrogen in the palladium catalyst (2H2 + O2 = 2H2O). The residual oxygen is reduced to below 5 ppm;

      The water generated is preliminarily removed from the nitrogen gas of having reacted oxygen through a cooler and a refrigerator, and further removed by two dryers, in which the molecular sieves are filled, one of them adsorbing the water and the other subjecting to being desorbed at high temperature after it adsorbs water to saturation. The normal-pressure dew point of the nitrogen gas can finally reach less than -60 ℃.

      The gas purified is conveyed through a pure nitrogen tank and then to nitrogen-using spots.

      氢脱氧纯化装置

      Hydrogen and nitrogen gas are homogeneously mixed, and hydrogen and oxygen contained in the nitrogen gas are fully contacted in a mixing tank, and then flow into a palladium catalyst reactor where oxygen reacts with hydrogen to form water to make oxygen vanish. Warnings of low temperature, low pressure and nitrogen purity are organized for the oxygen removers in order to effectively monitor the system.